PT test station for non-destructive dye penetrant crack testing
Modular, mobile inspection workstation designed to perform all necessary steps of the liquid penetrant inspection process – from cleaning and penetrant application to drying and developer application for small to medium-sized components at a single workstation.
The liquid penetrant inspection workstation provides a flexible solution for non-destructive liquid penetrant testing and can be individually configured to meet specific application requirements.
Data sheet PT test station as PDF document.
Features
- Test chamber with combined
UV and white light illumination through
energy-efficient and long-lasting
high-power LED lamp - Easy cleaning due to
stainless steel drip tray with
removable grid support - Sustainable reuse of wash water
through treatment with
activated carbon filter - Powerful exhaust fan
in combination with large-area
filter mats guarantees a minimum
spread of hazardous gas mixtures and
mixtures and spray mist - Easily accessible control panel for
individual control of lighting,
extraction and washing water pump
Technical data
nach DIN 54131 und VDE
Operating data
| Mains connections | 230 V, 50 Hz |
|---|---|
| Ambient conditions | 15 - 35 °C, 20 - 80 % rel. humidity |
Data sheet PT test station as PDF document
Order-No.: 300-008
More photos